BU-(C)-TYPE-S14

TECHNICAL DATA

  • Max. Operating Temperature: 90°C
  • Max. Short Circuit Temperature: (max. 5 sec.) 200°C
  • Rated Voltage: 250V
  • Min. Bending Radius: 10x Cable Outer Diameter
  • Production Standard: NEK TS 606, IEC 60092/353, IEC 60092/350-360, IEC 60332/1-2,
    IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
    IEC 61034 / 1-2 (DIN EN 50268 / 1-2), IEC60811 /403

CONSTRUCTION

  • Conductor: Tinned annealed stranded circular copper wire IEC 60228 Class 2
  • Insulation: Mica Glass Tape and Ethylene Propylene Rubber (EPR)
  • Twisting: Color coded cores twisted together to
    form a pair/triad
  • Collective Screen: Pairs/triples are laid-up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are identified by printed numbers on insulated conductors.
  • Inner Covering: Flame retardant and halogen-free compound Armour: Galvanised steel wire braid
  • Outer Sheath: Flame retardant, halogen-free thermoset compound, SHF2
  • Color: Grey

CODE of CABLE

  • BU (I+C)

APPLICATION

These cables are used for fixed installation for control, instrumentation and telecommunication in both explosion and safe areas, emergency and critical systems where requirement for fire resistance exists.

SECTION RANGE

  • From 0.75mm2 up to 2.5mm2

CONDUCTOR QUANTITY

  • From 1 core up to 24 cores

COLOUR CODE of CABLE

  • Insulation Colours code could be according to the
    International Standards or customer’s request/demand.
    * Other colours can be produced upon the customer
    requests.

Inquiry Form