PE-LSZH-OSCR-PVC-MC

TECHNICAL DATA

  • Max. Operating Temperature: 90°C
  • Rated Voltage: 300/500V
  • Min. Bending Radius: 7.5x Cable Outer Diameter
  • Production Standard: EN 50288-7

CONSTRUCTION

Conductor: Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and/or tinned on request)
Insulation: PE Polyethylene compound to EN 50290-2-23 Binder Tape: Polyester foil on overall cable core formed by stranded cores
Collective Screen: Aluminium/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
Outer Sheath: LSZH compound to EN 50290-2-27.
Blue for intrinsically safe cable, Black for UV resistant and/or non-intrinsically safe cable, Gray for indoor applications

CODE of CABLE

  • CU/PE/OSCR/LSZH; RE-2X(St)H-fl (MULTICORE)

INTRODUCTION

These cables used for connecting instruments and control
systems for analogue or digital signal transmission for indoor
and outdoor applications. These cables shall not be
connected directly to mains electricity supply or other low
impedance sources, since they are not designed to be used for
power supply.

SECTION RANGE

  • From 0.50mm2 up to 2.5mm2

CONDUCTOR QUANTITY

  • From 1 core up to 50 cores

COLOUR CODE of CABLE

  • Insulation Colours code could be according to the
    International Standards or customer’s request/demand.
    * Other colours can be produced upon the customer
    requests.